VT100C (94L)

Description:

The heat pump utilizes the energy in the air to heat the domestic water and can cover the annual consumption of 2-3 people, typically in an apartment complex.. It has a tank capacity of 94 liters and can produce up to approx. 420 liters of hot water per 24 hours. The heat pump is energy saving and allows up to 70% of the cost of hot water production to be saved.

 

Dimension: H: 1140mm D: 575mm B:540mm
Weight: 56kg
Voltage/Frequency: 230 V / 50 Hz
Connection effect VP: 340 Watt
Output: 897 Watts
High supplemental heat: 2000 Watts / 230 V
Connection power total: 2340 Watts / 230 V
Fuse at high supplemental heat Minimum 13 A
Thermostat for supplementary heat: Set at 65°C. Controlled via display
Refrigerant filling: See type plate
Air volume: Min. / Max. 100 / 200 m3/h
Air temperature: VT100C Min. +5°C to Max. +35°C
Water tank: VT100C Stainless steel, 94 L
Working pressure: Max 1MPa / 10 bar
Water temperature: Adjustable – Max. 62°C
Water capacity: 420 L / 24 h
Idling consumption at 20°C air temperature and 55°C WW water temperature – measured in accordance with the EN16147:2011 6 Watts / 24 t
Water connection:
Cold water: 3/4″ RG
Hot water: 3/4″ RG
Condensation: 1/2″ RG
Electronic: Yes
Air, inlet / outlet: Top / Top
Channel connection:: Ø160 mm
Legionella function: Yes

 

Model VT100C VT180C
Specification
+5°/35° X X
Electronic regulator X X
Supply air top (inlet + outlet) X X
Without heat exchanger X X
Heating rod 2000 watts X X
Air connections ø160mm X X
Legionellen Function X X
Solar Function X X
Vacation function X X
Boost Function X X
Timer Function (Optional) X X